What ASTM A536 Covers
ASTM A536 covers castings in ductile iron, also known as spheroidal graphite (SG) or nodular iron: cast iron in which the graphite is substantially spheroidal. The graphite form is what separates it from gray iron; see Ductile Iron vs Gray Iron.
Tensile properties are the core requirement. Every grade sets a minimum tensile strength, yield strength and elongation. Hardness, chemical composition, microstructure, pressure tightness, radiographic or magnetic particle inspection, dimensions and surface finish apply only when the contract or purchase order calls for them.
How to Read a Grade Number
The three numbers in a grade are its minimums in inch-pound units. 65-45-12 means a tensile strength ≥ 65 ksi (448 MPa), a yield strength ≥ 45 ksi (310 MPa) and an elongation ≥ 12%. The specification treats inch-pound values as the standard; MPa values are conversions for information.
Grades and Minimum Properties
| Grade | Minimum tensile strength | Minimum yield strength | Minimum elongation | Usual condition |
|---|---|---|---|---|
| 60-40-18 | 60 ksi (414 MPa) | 40 ksi (276 MPa) | 18% | Ferritizing anneal |
| 65-45-12 | 65 ksi (448 MPa) | 45 ksi (310 MPa) | 12% | As-cast |
| 80-55-06 | 80 ksi (552 MPa) | 55 ksi (379 MPa) | 6% | As-cast |
| 100-70-03 | 100 ksi (689 MPa) | 70 ksi (483 MPa) | 3% | Quench and temper, normalize and temper, or isothermal treatment |
| 120-90-02 | 120 ksi (827 MPa) | 90 ksi (621 MPa) | 2% | Quench and temper, normalize and temper, or isothermal treatment |
| For special applications | ||||
| 60-42-10 | 60 ksi (415 MPa) | 42 ksi (290 MPa) | 10% | — |
| 70-50-05 | 70 ksi (485 MPa) | 50 ksi (345 MPa) | 5% | — |
| 80-60-03 | 80 ksi (555 MPa) | 60 ksi (415 MPa) | 3% | — |
Recent Longtai ductile iron shipments have been in 60-40-18, 65-45-12 and 80-60-03; other grades can be produced on request. See Materials and standards.
Choosing a Grade
Moving up the table trades elongation for strength. A practical rule is to specify the lowest grade that carries the design load, keeping elongation where shock or sudden fracture is a risk.
- 60-40-18: the highest elongation and toughness of the general grades, for parts that see shock or must deform before cracking. In our catalog: the F-K pump diverter valve (84 kg) and valve body cover (28 kg).
- 65-45-12: a balance of strength and elongation, and the grade of most slurry pump castings in our catalog, from the suction side casing (980 kg) and suction plate (159 kg) to the stuffing box (80 kg).
- 80-55-06: higher strength where 6% elongation is sufficient, usually as-cast.
- 100-70-03 and 120-90-02: strength reached through heat treatment, for parts where strength and wear resistance matter more than elongation. The specification cautions that quenched and tempered ductile iron may have substantially lower fatigue strength than as-cast material of the same hardness.

How A536 Properties Are Verified
Tensile properties are measured on test bars machined from separately cast coupons, a Y-block, keel block or modified keel block, poured from the same ladle or heat as the castings and given the same heat treatment. If the purchaser states no preference, the manufacturer selects the coupon.
The specification also notes that no precise relationship can be stated between the properties at various locations in a casting and those of a test bar, as section size and cooling rate differ. If properties in the casting itself matter, state the requirement on the drawing or purchase order.
At Longtai, every heat is analyzed on a SPECTRO optical emission spectrometer (29+ elements) before pouring. Test bars are pulled on a 30 t tensile testing machine for tensile strength and elongation, hardness is checked in HB or HRC, and metallography confirms the graphite form. See Melting for how chemistry is controlled.
A536 Equivalents in GB/T, EN and JIS
| USA · ASTM A536 | China · GB/T 1348 | Europe · EN 1563 | Japan · JIS G5502 |
|---|---|---|---|
| 60-40-18 | QT400-18 | EN-GJS-400-18 | FCD400-18 |
| 65-45-12 | QT450-10 | EN-GJS-450-10 | FCD450-10 |
| 80-60-03 | QT600-3 | EN-GJS-600-3 | FCD600-3 |
The equivalents are close but not identical, and the designations show it. QT450-10 and EN-GJS-450-10 call for 450 MPa and 10% elongation; 65-45-12 calls for 65 ksi (448 MPa) and 12%. QT400-18 calls for 400 MPa against 60 ksi (414 MPa) for 60-40-18. A casting certified to one standard is therefore not automatically compliant with another. Quote the governing standard on the drawing so that test bars are made and evaluated to it.
What to State on the Drawing or RFQ
- Standard and grade, for example ASTM A536 65-45-12, with the edition if your quality system requires it.
- Test coupon type, if you have a preference: Y-block, keel block or modified keel block.
- Requirements beyond tensile properties, such as a hardness range, nodularity or microstructure, pressure tightness, or radiographic or magnetic particle inspection. A536 applies these only when the order calls for them.
- Quantity and supply condition: as-cast, machined or painted.
Not sure which grade suits your part? Send your drawing for engineering review. We reply within 72 hours.